Single & double fire-rated doors

Single and double fire-rated steel doors for protected project openings.

Choose a single leaf, equal pair or unequal pair around the opening size, movement pattern, required rating and approved hardware set. Techno Door coordinates the complete assembly from its Al Rai manufacturing base.

Leaf arrangement

One door schedule. Three practical configurations.

The correct arrangement is driven by clear opening, daily traffic, equipment access, escape strategy and the size limits of the selected approved assembly.

  • Single leaf for standard protected openings
  • Equal double leaves for balanced wide access
  • Unequal pair with active and inactive leaves
  • Vision panels where the approved system permits
Equal double fire-rated steel doors in a finished interior visualization

Configuration guide

Select around use—not appearance alone.

Final dimensions and ratings must remain within the selected listing and project approval.

ArrangementTypical useCoordination focus
Single leafPersonnel, service and circulation openingsHanding, closer, lock and wall condition
Equal pairWide corridors, plant and equipment accessPanic devices, coordinator and active leaf
Unequal pairNormal daily access plus occasional clearanceInactive-leaf bolts, sequencing and clear width
Single solid fire-rated steel door visualization

Documented scope

Coordinate the complete approved assembly.

The current Intertek listing records selected single-leaf assemblies up to 180 minutes and selected double-leaf assemblies up to 120 minutes. Applicability depends on the final size, construction, frame, hardware, glazing, anchors and installation.

Review certification references

Quotation checklist

Send the details that change the assembly.

A complete opening schedule reduces assumptions and shortens technical review.

01Clear opening and wall type
02Required rating and leaf arrangement
03Handing, finish and hardware schedule

Project questions

Clear answers before quotation.

Send the opening schedule and available specification for a project-specific review.

When should a project use a single or double fire-rated door?

Single-leaf doors suit standard personnel openings. Equal-pair and unequal-pair double doors suit wider circulation, equipment movement and controlled access requirements, subject to the approved assembly size.

Can panic hardware and door closers be coordinated?

Yes. Panic devices, closers, locks, coordinators, flush bolts and related preparation are selected as part of the complete approved door assembly.

What determines the final fire rating?

The listed assembly, opening size, leaf arrangement, frame, hardware, glazing where used, wall condition, anchors and installation method determine the applicable rating.

Steel door manufacturing and project support

Bring us the opening, rating or fabrication brief.

Our team will help define a practical, project-ready solution.

Request a Quote
WA
Call nowWhatsApp